HKS Turbo Timer X (41001-AK012)

HKS

$88.20 
HKS-41001-AK012

Quantity: 



We price match!

The all new HKS Turbo Timer X is the 10th Generation Model from a 35-year history of turbo timers. This timer is a direct-replacement upgrade for the old HKS Type-0 (41001-AK009) and will work with your existing HKS harness.

Vehicle Fitment:
Turbocharged Vehicles
• Must use the ignition key to start
• Not compatible with push-to-start

HKS Harness:
If you are installing this brand new into your car, you'll also need a harness. We sell the turbo timer alone or paired with a vehicle specific harness listed in the purchase menu.

Idle Setting Times:
1, 3, 5, 10 and 30 minutes.

Includes:
Turbo Timer and install accessories as pictured

Which Harness do I need for my HKS Turbo Timer?

These are the harnesses we carry. If you don't see the one you need below, check out the HKS Timer Harness Application Chart and shoot us a message!
Part Number: Vehicle Fitment:
4103-RA001 Universal Application
4103-RT007 1997-1998 Toyota Supra MK4
4103-RM004 CD9A/CE9A Evolution I II III
CN9A Evolution IV
CP9A Evolution V VI
4103-RM001 1990-1994 Eclipse GST/GSX
1990-1994 Talon TSi
1990-1994 Laser RS
1991-1993 Galant VR4
1991-1999 3000GT VR-4
1991-1996 Stealth R/T
4103-RM006 2008-2015 Evolution X CZ4A
2001-2006 Evolution VII VIII IX CT9A
1995-1999 Eclipse GST/GSX
1995-1998 Talon TSi
4103-RF002 2002-2007 Subaru WRX
2004-2007 Subaru STi
4103-AF006 2008-2014 Subaru WRX
2008-2014 Subaru STi

 

Additional Info from HKS:



10th Model
Simple and Highly Operable Model from 35-year History.

Function specialized in after-idling.
Simple, and easy to use

• DC12V Negative Ground (Operation Voltage: DC101~16V)
• Large Capacity Relay Equipped
• Ignition: 25A / Accessary: 25A
• Stand-by Current: 10mA or lower
• Operating Temperature: -20~60℃ (-4 to 140°F)
• Setting Time Range: :1, 3, 5, 10, and 30 min.



Example of One Minute Time Range: Frequent after-idling for daily use.
Idling takes place after street driving, commuting, etc.
It is convenient when a driver has to leave the car right after the engine is shut off.



Example of 3 Minutes Time Range: Effective after-idling after driving a highway.
After idling can cool down the turbine and/or engine oil heated up by continuous high speed driving, and the engine shut off without imposing a load to the turbine and/or engine; therefore, the durability of the engine and engine oil is improved.



Example of 5 Minutes Time Range: Effective after-idling after circuit driving
When high load is applied to an engine, and an engine runs at a high speed, the engine and turbine may become in a condition close to a limit. With Turbo Timer, after-idling takes place even if the ignition is turned off by mistake so the engine and turbine may not be damaged.



Example of 10 Minutes Time Range: To keep the interior temperature when leaving a vehicle for a short time
With Turbo Timer, a driver can lock the vehicle door even while running an engine; it allows the vehicle interior temperature maintain when leaving the vehicle for ten minutes or so while reducing a load to a battery.



Example of 30 Minutes Time Range: To maintain the vehicle interior temperature in summer or winter
Maximum timer duration is 30 minutes. A long after-idling enables the vehicle interior temperature to be maintained for a long time.
(A long after-idling may not be allowed depending on the area, facility, local regulation, etc.)



Functions:
 Single button control and red LED numerical display simplify operation and improve visibility.
 5 time ranges selectable between 1, 3, 5, 10, and 30min. Maximum timer duration is 30 minutes.
 Accurate time duration can be selected by manual setting.
 Handbrake detective safety circuit
 High capacity relay
 Timer operation stops under unstable conditions caused by low voltage of a battery, etc.

Application:
 Turbo vehicles that start the engine using the ignition key.
 Not applicable to a vehicle equipped with the push-button ignition.
 Existing Turbo Timer Harness is compatible.
 This product is not compatible some vehicles. Refer to the application list before purchasing this product.

Features:
 Simple after-idling function and easy operation
 Optimal touch button size for simple operation
 Wavy panel design around the button for better operability. Capable of operating the button even in the dark.
 Accurate setting is possible even by quick operation.
 One-digit display for easy recognition of the set time
 Time duration changed simply by pushing the button. Intuitive operations is possible.
 Selecting "OFF mode" turns off the display and buzzer.

Extension of Timer Duration:
 Maximum timer duration is 30 minutes.
 Not only protecting the turbocharger, but also maintaining the temperature in a vehicle in summer and winter is possible.

Buy HKS products at www.stmtuned.com!
© All content is property of STM Tuned Inc

Customer Reviews

Based on 2 reviews
100%
(2)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
t
thomas freeman (Atlanta, GA, US)
GREAT 1ST TIME CUSTOMER EXPERIENCE

Purchased the HKS Turbo Timer X and had an extremely smooth and timely delivery! Thanks!

C
Christopher C (Norfolk, VA, US)
The hks turbo timer 4g63t eclipse install

Effortless for anyone with half a brain and im 90% sure a baboon could install this.
Easy install, great sleek look, works excellent to tap into the ignition for gauges and other electronics, 10 of 10


WARNING:
Cancer and Reproductive Harm
www.p65warnings.ca.gov